10-80kVA Three Phase High Frequency Online UPS Power Supply with No Transfer Time
 Recommended by CCCME
Recommended by CCCME
                        - Product Details
- Company Profile
1.Full DSP control technology 2.Output power factor up to 0.9,IGBT rectifier 3.Intelligent SNMP+USB+EPO (optional) 4.RS232/RS485/dry contact communication port 5.ECO fuction 6.Maintenance switch 7.DC cold start function 8.Intelligent fan speed control
3W3 10-80kVA
Main feature
1.Full DSP control technology
2.Output power factor up to 0.9,IGBT rectifier
3.Intelligent SNMP+USB+EPO (optional)
4.RS232/RS485/dry contact communication port
5.ECO fuction
6.Maintenance switch
7.DC cold start function
8.Intelligent fan speed control
Application
1.Data center 
2.IT room
3.Commercial facility
4.Precision instrument
5.Telecom system
6.Rack device
Specification
| Model | 3W3RX10K S/L | 3W3IX20K S/L | 3W3IX30K S/L | 3W3IX40K S/L | 3W3IX60K L | 3W3IX80KL | |||||
| Capacity | 10kVA | 20kVA | 30kVA | 40kVA | 60kVA | 80kVA | |||||
| Input features | |||||||||||
| Input voltage(Vac) | 380(-45%~+25%),-45%~-20% | ||||||||||
| Bypass voltage(V) | +15%(+20% optional)/-25% | ||||||||||
| Frequency(HZ) | 40—70Hz Automatically select synchronization range according to grid frequency | ||||||||||
| Phase | 3φ4W+PE | ||||||||||
| Power Factor | ≥0.99 | ||||||||||
| Battery voltage(Vdc) | 240 | ±192 | |||||||||
| Quantity of battery(Pcs) | 16-20 can be adjusted | 28-32 can be adjusted | |||||||||
| 
 Battery type | 
 20*7Ah12V /External 
 | 
 32*9Ah 12V /External 
 | 
 32*12Ah 12V /External 
 | 
 32*12Ah 12V /External 
 | 
 External | ||||||
| Output features | |||||||||||
| Power factor | 0.9 | 0.8/0.9 | |||||||||
| Voltage(V) | 380/400/415±1% | ||||||||||
| Frequency(HZ) | Mains normal,Same as input;Mains abnormal,50±0.2% | ||||||||||
| Transfer Time(ms) | 0 | ||||||||||
| Efficiency (AC mode @ full loads) | ﹥93% | ﹥94% 
 | |||||||||
| N+X in parallel | 3pcs | 8pcs | |||||||||
| Waveform | Linear Load THD<3%;Non Linear Load THD<5% | ||||||||||
| Overload capacity | 125% full load keep 10 mins,150% full load keep 60s | ||||||||||
| Crest factor | >3:1 | ||||||||||
| Others | |||||||||||
| Manual maintenance bypass | with no transfer time bypass maintenance switch | ||||||||||
| Communication | RS232/RS485/dry contact(SNMP/USB are optional) | ||||||||||
| Noise (dB) | <58(within 1 meter) | ||||||||||
| Alarm | Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection | ||||||||||
| Protection | Input over-voltage protection, battery under voltage protection, overload protection, short circuit protection, over temperature protection | ||||||||||
| Cooling way | Forced cooling | ||||||||||
| Working Temperature(℃) | 0~40 | ||||||||||
| Humidity | 0~95%,no condensing | ||||||||||
| EMC | GB7260.2 | ||||||||||
| Size(D×W×H) (mm) | 250*592*826/576 | 420*643*956 | 470*710*1150 | 600*810*1830 | |||||||
| Weight(KG) | 109/38 | 183/82 | 222/110 | 226/114 | 145 | 306 | |||||
Note:
Because the products are continuously improved, please contact the company or dealer to inquiry the latest specification.
 
 
             
                             
                             
                             
						 Chat Now!
Chat Now!
						     Send Inquiry
Send Inquiry Experience Member
Experience Member 0
0 Chinese Supplier
Chinese Supplier



 
	 
		